400-0066-400

Rat Estrogen-related Receptor Alpha (EERα) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Rat Estrogen-related Receptor Alpha (EERα) ELISA Kit
Product Name:

Rat Estrogen-related Receptor Alpha (EERα) ELISA Kit

Cat.#:

JL52509

Regulatory Status:
Alternative:

Estrogen-related receptor alpha

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.156-10ng/mL
Sensitivity:
0.077ng/mL
Specificity:
This kit recognizes Rat EERα in samples. No significant cross-reactivity or interference between Rat EERα and analogues was observed.
Sample Type:
Serum;plasma;tissue homogenates;cell lysates;cell culture supernates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Cancer
  • Rat Estrogen-related Receptor Alpha (EERα) ELISA Kit
  • Rat Estrogen-related Receptor Alpha (EERα) ELISA Kit
  • Rat Estrogen-related Receptor Alpha (EERα) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| EERα

Estrogen-related receptor alpha (ERRα), also known as NR3B1 (nuclear receptor subfamily 3, group B, member 1), is a nuclear receptor that is encoded by the ESRRA (Estrogen Related Receptor Alpha) gene.[5][6] ERRα was originally cloned by DNA sequence homology to the estrogen receptor alpha (ERα, NR3A1),but subsequent ligand binding and reporter-gene transfection experiments demonstrated that estrogens did not regulate ERRα.Currently, ERRα is considered an orphan nuclear receptor.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (ng/mL) 10 5 2.5 1.25 0.625 0.312 0.156 0
OD 2.08 1.31 0.75 0.5 0.33 0.25 0.21 0.09
Corrected OD 1.99 1.22 0.66 0.41 0.24 0.16 0.12 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Rat EERα spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 84-101 96
Plasma(n=8) 92-106 103
Cell Culture Supernates(n=8) 96-107 105





 

| Linearity

Samples were spiked with high concentrations of Rat EERα and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4) Cell Culture Supernates(n=4)
1 : 2 Range (%) 84-95 88-96 90-110
Average (%) 91 93 96
1 : 4 Range (%) 89-103 87-108 105-114
Average (%) 94 98 107







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
280 / 280
96T
1
460 / 460
Top