400-0066-400

Rat G-Protein Coupled Receptor 30 (GPR30) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Rat G-Protein Coupled Receptor 30 (GPR30) ELISA Kit
Product Name:

Rat G-Protein Coupled Receptor 30 (GPR30) ELISA Kit

Cat.#:

JL31482

Regulatory Status:
Alternative:

G Protein Coupled Estrogen Receptor 1; GPER; CMKRL2; DRY12; FEG-1; GPCR-Br; LERGU; LyGPR; Membrane estrogen receptor; Chemoattractant receptor-like 2; Flow-induced endothelial G-protein coupled receptor 1

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
78-5000pg/mL
Sensitivity:
38.7pg/mL
Specificity:
This kit recognizes Rat GPR30 in samples. No significant cross-reactivity or interference between Rat GPR30 and analogues was observed.
Sample Type:
Tissue homogenates;cell lysates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Metabolism
  • Rat G-Protein Coupled Receptor 30 (GPR30) ELISA Kit
  • Rat G-Protein Coupled Receptor 30 (GPR30) ELISA Kit
  • Rat G-Protein Coupled Receptor 30 (GPR30) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| GPR30

G protein-coupled estrogen receptor 1 (GPER), also known as G protein-coupled receptor 30 (GPR30), is a protein that is encoded by the GPER gene. GPER binds to and is activated by the female sex hormone estradiol and is responsible for some of the rapid effects that estradiol has on cells.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (pg/mL) 5000 2500 1250 625 312 156 78 0
OD 2.36 1.49 0.95 0.54 0.35 0.26 0.21 0.09
Corrected OD 2.27 1.4 0.86 0.45 0.26 0.17 0.12 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Rat GPR30 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Tissue Homogenates(n=8) 85-101 96
Cell Lysates(n=8) 96-108 105





 

| Linearity

Samples were spiked with high concentrations of Rat GPR30 and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Tissue Homogenates(n=4) Cell Lysates(n=4)
1 : 2 Range (%) 84-95 90-110
Average (%) 93 92
1 : 4 Range (%) 89-104 105-115
Average (%) 99 108







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
280 / 280
96T
1
460 / 460
Top