400-0066-400

Rat GABA type A receptor-associated Protein (Gabarap) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Rat GABA type A receptor-associated Protein (Gabarap) ELISA Kit
Product Name:

Rat GABA type A receptor-associated Protein (Gabarap) ELISA Kit

Cat.#:

JL20017

Regulatory Status:
Alternative:

ATG8A;FLC 3B;FLC3B;FLJ25768;GABA type A receptor associated protein;GABA(A) receptor associated protein;GABA(A) receptor-associated protein;GABARAP a;GABARAP;Gamma aminobutyric acid receptor associated protein;Gamma-aminobutyric acid receptor-associated p

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
15.6-1000pg/mL
Sensitivity:
7.7pg/mL
Specificity:
This kit recognizes Rat Gabarap in samples. No significant cross-reactivity or interference between Rat Gabarap and analogues was observed.
Sample Type:
Serum;plasma;tissue homogenates;cell lysates;cell culture supernates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Neuroscience
  • Rat GABA type A receptor-associated Protein (Gabarap) ELISA Kit
  • Rat GABA type A receptor-associated Protein (Gabarap) ELISA Kit
  • Rat GABA type A receptor-associated Protein (Gabarap) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| Gabarap

Gamma-aminobutyric acid receptor-associated protein is a protein that encoded by the GABARAP gene.Gamma-aminobutyric acid A receptors [GABA(A) receptors] are ligand-gated chloride channels that mediate inhibitory neurotransmission. This protein clusters neurotransmitter receptors by mediating interaction with the cytoskeleton.GABARAP has an important function in autophagosome mediated autophagy, since it is crucial for autophagosome formation and sequestration of cytosolic cargo into double-membrane vesicles, leading to subsequent degradation after fusion with lysosomes.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (pg/mL) 1000 500 250 125 62.5 31.2 15.6 0
OD 2.72 1.63 0.9 0.54 0.35 0.27 0.22 0.08
Corrected OD 2.64 1.55 0.82 0.46 0.27 0.19 0.14 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Rat Gabarap spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 84-101 96
Plasma(n=8) 92-106 104
Cell Culture Supernates(n=8) 96-108 105





 

| Linearity

Samples were spiked with high concentrations of Rat Gabarap and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4) Cell Culture Supernates(n=4)
1 : 2 Range (%) 84-95 88-96 90-110
Average (%) 91 93 96
1 : 4 Range (%) 89-103 87-108 105-114
Average (%) 94 98 107







 