Product Name:
Mouse Classical Transient Receptor Potential (TRPC) ELISA Kit
Cat.#:
JL52412
Regulatory Status:
Alternative:
classical transient receptor potential
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.156-10ng/mL
Sensitivity:
0.079ng/mL
Specificity:
This kit recognizes Mouse TRPC in samples. No significant cross-reactivity or interference between Mouse TRPC and analogues was observed.
Sample Type:
Serum;plasma;tissue homogenates;cell lysates;cell culture supernates and other biological fluids
Assay Procedure:
Research Area:
Signal Transduction
Product Datasheets
| TRPC
TRPC is a family of transient receptor potential cation channels in animals.TRPC channels form the subfamily of channels in humans most closely related to drosophila TRP channels. Structurally, members of this family possess a number of similar characteristics, including 3 or 4 ankyrin repeats near the N-terminus and a TRP box motif containing the invariant EWKFAR sequence at the proximal C-terminus. These channels are non-selectively permeable to cations, with a prevalence of calcium over sodium variable among the different members. Many of TRPC channel subunits are able to coassemble.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (ng/mL) | 10 | 5 | 2.5 | 1.25 | 0.625 | 0.312 | 0.156 | 0 |
| OD | 2.16 | 1.45 | 0.93 | 0.56 | 0.38 | 0.28 | 0.21 | 0.08 |
| Corrected OD | 2.08 | 1.37 | 0.85 | 0.48 | 0.3 | 0.2 | 0.13 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Mouse TRPC spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Serum(n=8) | 84-101 | 96 |
| Plasma(n=8) | 92-105 | 102 |
| Cell Culture Supernates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Mouse TRPC and diluted with Universal Diluent to produce samples with values within the range of the assay.| Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
| 1 : 2 | Range (%) | 84-95 | 88-97 | 90-110 |
| Average (%) | 91 | 94 | 96 | |
| 1 : 4 | Range (%) | 89-103 | 87-108 | 105-115 |
| Average (%) | 94 | 98 | 108 |
Size
Quantity
Price ($)
48T
1
280 / 280
96T
1
460 / 460