Product Name:
Mouse Soluble Intercellular Adhesion Molecule 1 (sICAM-1) ELISA Kit
Cat.#:
JL12292
Regulatory Status:
Alternative:
sICAM-1
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
3.12-200ng/mL
Sensitivity:
1.89ng/mL
Specificity:
This kit recognizes Mouse sICAM-1 in samples. No significant cross-reactivity or interference between Mouse sICAM-1 and analogues was observed.
Sample Type:
Serum;plasma;tissue homogenates;cell lysates;cell culture supernates and other biological fluids
Assay Procedure:
Research Area:
Immunology
Product Datasheets
| sICAM-1
Soluble cell adhesion molecules (sCAMs) are a class of cell adhesion molecule (CAMs - cell surface binding proteins) that may represent important biomarkers for inflammatory processes involving activation or damage to cells such as platelets and the endothelium.They include soluble isoforms of the cell adhesion molecules ICAM-1, VCAM-1, E-selectin and P-selectin (distinguished as sICAM-1, sVCAM-1, sE-selectin and sP-selectin). The cellular expression of CAMs is difficult to assess clinically, but these soluble forms are present in the circulation and may serve as markers for CAMs.Research studies have used sCAMs as biomarkers to measure correlations with nutrients or nutrient levels as significant, or not.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (ng/mL) | 200 | 100 | 50 | 25 | 12.5 | 6.25 | 3.12 | 0 |
| OD | 2.44 | 1.87 | 1.29 | 0.83 | 0.58 | 0.38 | 0.27 | 0.08 |
| Corrected OD | 2.36 | 1.79 | 1.21 | 0.75 | 0.5 | 0.3 | 0.19 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Mouse sICAM-1 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Serum(n=8) | 84-101 | 96 |
| Plasma(n=8) | 92-105 | 102 |
| Cell Culture Supernates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Mouse sICAM-1 and diluted with Universal Diluent to produce samples with values within the range of the assay.| Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
| 1 : 2 | Range (%) | 84-95 | 88-96 | 90-110 |
| Average (%) | 91 | 93 | 96 | |
| 1 : 4 | Range (%) | 89-103 | 87-108 | 105-115 |
| Average (%) | 95 | 98 | 108 |
Size
Quantity
Price ($)
48T
1
280 / 280
96T
1
460 / 460