400-0066-400

Mouse 78 kDa Glucose-regulated Protein (Grp78) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Mouse 78 kDa Glucose-regulated Protein (Grp78) ELISA Kit
Product Name:

Mouse 78 kDa Glucose-regulated Protein (Grp78) ELISA Kit

Cat.#:

JL20502

Regulatory Status:
Alternative:

MIF2; BIP; HSPA5; Immunoglobulin heavy chain-binding protein; Glucose Regulated Protein 78; Binding Immunoglobulin Protein; Endoplasmic reticulum lumenal Ca binding grp78

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.15-10ng/mL
Sensitivity:
0.08ng/mL
Specificity:
This kit recognizes Mouse Grp78 in samples. No significant cross-reactivity or interference between Mouse Grp78 and analogues was observed.
Sample Type:
Serum;plasma;tissue homogenates;cell lysates;cell culture supernates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Cancer
  • Mouse 78 kDa Glucose-regulated Protein (Grp78) ELISA Kit
  • Mouse 78 kDa Glucose-regulated Protein (Grp78) ELISA Kit
  • Mouse 78 kDa Glucose-regulated Protein (Grp78) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| Grp78

78 kDa glucose-regulated protein(GRP-78) also known as binding immunoglobulin protein (BiPS) or heat shock 70 kDa protein 5 (HSPA5) is a protein that is encoded by the HSPA5 gene. GRP-78 is a HSP70 molecular chaperone located in the lumen of the endoplasmic reticulum (ER) that binds newly synthesized proteins as they are translocated into the ER, and maintains them in a state competent for subsequent folding and oligomerization. GRP-78 is also an essential component of the translocation machinery and plays a role in retrograde transport across the ER membrane of aberrant proteins destined for degradation by the proteasome. GRP-78 is an abundant protein under all growth conditions, but its synthesis is markedly induced under conditions that lead to the accumulation of unfolded polypeptides in the ER.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (ng/mL) 10 5 2.5 1.25 0.62 0.31 0.15 0
OD 2.52 1.96 1.38 0.97 0.55 0.31 0.19 0.08
Corrected OD 2.44 1.88 1.3 0.88 0.47 0.23 0.11 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Mouse Grp78 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 84-101 96
Plasma(n=8) 92-105 102
Cell Culture Supernates(n=8) 96-108 105





 

| Linearity

Samples were spiked with high concentrations of Mouse Grp78 and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4) Cell Culture Supernates(n=4)
1 : 2 Range (%) 84-95 88-96 90-110
Average (%) 91 93 96
1 : 4 Range (%) 89-103 87-108 105-115
Average (%) 94 98 108







 