400-0066-400

Human lymphatic vessel endothelial hyaluronan receptor 1(LYVE1) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Human lymphatic vessel endothelial hyaluronan receptor 1(LYVE1) ELISA Kit
Product Name:

Human lymphatic vessel endothelial hyaluronan receptor 1(LYVE1) ELISA Kit

Cat.#:

JL29140

Regulatory Status:
Alternative:

LYVE-1; CRSBP1; HAR; XLKD1

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
31.25-2000pg/mL
Sensitivity:
15.52pg/mL
Specificity:
This kit recognizes Human LYVE1 in samples. No significant cross-reactivity or interference between Human LYVE1 and analogues was observed.
Sample Type:
Serum, plasma, cell culture supernatants and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Cancer
  • Human lymphatic vessel endothelial hyaluronan receptor 1(LYVE1) ELISA Kit
  • Human lymphatic vessel endothelial hyaluronan receptor 1(LYVE1) ELISA Kit
  • Human lymphatic vessel endothelial hyaluronan receptor 1(LYVE1) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| LYVE1

Lymphatic vessel endothelial hyaluronan receptor 1 (LYVE1), also known as extracellular link domain-containing 1 (XLKD1), is a link domain-containing hyaluronan-binding protein that binds to hyaluronic acid (HA) and is homologous to the major HA receptor CD44. It is encoded by the LYVE1 gene. LYVE1 is a type I integral membrane glycoprotein. It acts as a receptor that binds both soluble and immobilized hyaluronic acid. This protein may play a role in lymphatic hyaluronan trafficking and in tumor metastasis. LYVE-1 is a cell surface receptor on lymphatic endothelial cells and can be used as a lymphatic endothelial cell marker, allowing these cells to be isolated for experimental purposes.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (pg/mL) 2000 1000 500 250 125 62.5 31.25 0
OD 2 1.56 1.14 0.76 0.49 0.33 0.24 0.1
Corrected OD 1.9 1.46 1.04 0.66 0.39 0.23 0.14 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Human LYVE1 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 86-101 96
Plasma(n=8) 92-105 104
Cell Culture Supernates(n=8)  98-110 102





 

| Linearity

Samples were spiked with high concentrations of Human LYVE1 and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4) Cell Culture Supernates(n=4)
1 : 2 Range (%) 82-93 88-96 93-110
Average (%) 93 93 97
1 : 4 Range (%) 88-103 87-108 105-113
Average (%) 94 98 109







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
360 / 360
96T
1
640 / 640
Top