Product Name:
Human Thioredoxin reductase (TrxR) ELISA Kit
Cat.#:
JL12013
Regulatory Status:
Alternative:
cytoplasmic ; Gene associated with retinoic and IFN-induced mortality 12 protein; GRIM 12 ; GRIM-12 ; GRIM12 ; KDRF ; KM 102 derived reductase like factor ; MGC9145 ; Oxidoreductase ; Thioredoxin reductase 1 ; Thioredoxin reductase 1 cytoplasmic ; Thiored
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.15-10ng/mL
Sensitivity:
0.07ng/mL
Specificity:
This kit recognizes Human TrxR in samples. No significant cross-reactivity or interference between Human TrxR and analogues was observed.
Sample Type:
Serum, plasma, cell culture supernatant and other biological fluids
Assay Procedure:
Research Area:
Metabolism
Product Datasheets
| TrxR
Thioredoxin reductase (TrxR) is the only known enzyme capable of catalyzing the reduction of thioredoxin, making it a core component of the thioredoxin system. Together with thioredoxin (Trx) and NADPH, this system most generally describes the method by which cells form reduced disulfide bonds. Electrons are acquired by TrxR from NADPH and transferred to the active site of Trx, which then proceeds to reduce protein disulfides or other substrates. The Trx system is present in all biological cells, and its evolutionary history is linked to DNA as genetic material, defense against oxidative damage caused by oxygen metabolism, and redox signaling using molecules such as hydrogen peroxide and nitric oxide.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (ng/mL) | 10 | 5 | 2.5 | 1.25 | 0.62 | 0.31 | 0.15 | 0 |
| OD | 2.22 | 1.56 | 0.92 | 0.63 | 0.42 | 0.25 | 0.18 | 0.08 |
| Corrected OD | 2.14 | 1.48 | 0.84 | 0.55 | 0.34 | 0.17 | 0.1 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human TrxR spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Serum(n=8) | 84-101 | 96 |
| Plasma(n=8) | 92-105 | 102 |
| Cell Culture Supernates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Human TrxR and diluted with Universal Diluent to produce samples with values within the range of the assay.| Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
| 1 : 2 | Range (%) | 84-95 | 88-97 | 90-110 |
| Average (%) | 91 | 93 | 96 | |
| 1 : 4 | Range (%) | 89-103 | 87-108 | 105-115 |
| Average (%) | 94 | 98 | 108 |
Size
Quantity
Price ($)
48T
1
360 / 360
96T
1
640 / 640