Home > Sandwich ELISA Kits > Human soluble Programmed Cell Death Protein 1 Ligand 2 (sPD-L2) ELISA Kit
Product Name:
Human soluble Programmed Cell Death Protein 1 Ligand 2 (sPD-L2) ELISA Kit
Cat.#:
JL53847
Regulatory Status:
Alternative:
sPD-L2
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.156-10ng/mL
Sensitivity:
0.072ng/mL
Specificity:
This kit recognizes Human sPD-L2 in samples. No significant cross-reactivity or interference between Human sPD-L2 and analogues was observed.
Sample Type:
Tissue homogenates;cell lysates;cell culture supernates and other biological fluids
Assay Procedure:
Research Area:
Signal Transduction
Product Datasheets
| sPD-L2
Programmed cell death 1 ligand 2 (also known as PD-L2, B7-DC) is an immune checkpoint receptor ligand which plays a role in negative regulation of the adaptive immune response.PD-L2 is one of two known ligands for Programmed cell death protein 1 (PD-1).PD-L2 binds to its receptor PD-1 with dissociation constant Kd of 11.3 nM.Binding to PD-1 can activate pathways inhibiting TCR/BCR-mediated immune cell activation. PD-L2 plays an important role in immune tolerance and autoimmunity.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (ng/mL) | 10 | 5 | 2.5 | 1.25 | 0.625 | 0.312 | 0.156 | 0 |
| OD | 2.48 | 1.65 | 1.07 | 0.71 | 0.45 | 0.28 | 0.19 | 0.09 |
| Corrected OD | 2.39 | 1.56 | 0.98 | 0.62 | 0.36 | 0.19 | 0.01 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human sPD-L2 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Tissue Homogenates(n=8) | 84-101 | 96 |
| Cell Lysates(n=8) | 92-105 | 102 |
| Cell Culture Supernates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Human sPD-L2 and diluted with Universal Diluent to produce samples with values within the range of the assay.| Tissue Homogenates(n=4) | Cell Lysates(n=4) | Cell Culture Supernates(n=4) | ||
| 1 : 2 | Range (%) | 85-95 | 88-96 | 90-110 |
| Average (%) | 91 | 93 | 96 | |
| 1 : 4 | Range (%) | 89-103 | 87-108 | 105-114 |
| Average (%) | 94 | 98 | 108 |
Size
Quantity
Price ($)
48T
1
320 / 320
96T
1
516 / 516