Human Solute Carrier Family 7, Member 11 (SLC7A11) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Human Solute Carrier Family 7, Member 11 (SLC7A11) ELISA Kit
Product Name:

Human Solute Carrier Family 7, Member 11 (SLC7A11) ELISA Kit

Cat.#:

JL15881

Regulatory Status:
Alternative:

CCBR1; xCT; Cystine/Glutamate Transporter;Cationic Amino Acid Transporter;y+ System; Amino acid transport system xc-; Calcium channel blocker resistance protein CCBR1;Solute Carrier Family 7; Member 11

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.156-10ng/mL
Sensitivity:
0.079ng/mL
Specificity:
This kit recognizes Human SLC7A11 in samples. No significant cross-reactivity or interference between Human SLC7A11 and analogues was observed.
Sample Type:
Tissue homogenates;cell lysates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Metabolism
  • Human Solute Carrier Family 7, Member 11 (SLC7A11) ELISA Kit
  • Human Solute Carrier Family 7, Member 11 (SLC7A11) ELISA Kit
  • Human Solute Carrier Family 7, Member 11 (SLC7A11) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| SLC7A11

Cystine/glutamate transporter is an antiporter that is encoded by the SLC7A11 gene.SLC7A11 plays an important role in glutathione production throughout nervous and non-nervous tissues. In the nervous system, SLC7A11 regulates synaptic activity by stimulating extrasynaptic receptors and performs nonvesicular glutamate release. This gene is highly expressed by astrocytes and couples the uptake of one molecule of cystine with the release of one molecule of glutamate. The expression of Xc- was detected throughout the brain with higher expression found in the basolateral amygdala, the retina and the prefrontal cortex. The inhibition of system Xc- has been found to alter a number of behaviors, which suggests that it plays a key role in excitatory signaling.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (ng/mL) 10 5 2.5 1.25 0.625 0.312 0.156 0
OD 2.22 1.56 0.92 0.63 0.42 0.25 0.18 0.08
Corrected OD 2.14 1.48 0.84 0.55 0.34 0.17 0.1 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Human SLC7A11 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Tissue Homogenates(n=8) 84-101 96
Cell Lysates(n=8) 92-105 102





 

| Linearity

Samples were spiked with high concentrations of Human SLC7A11 and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Tissue Homogenates(n=4) Cell Lysates(n=4)
1 : 2 Range (%) 84-95 88-96
Average (%) 92 93
1 : 4 Range (%) 89-103 90-108
Average (%) 94 98







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
280 / 280
96T
1
460 / 460