Product Name:
Human Programmed Cell Death Protein 1 (PDCD1) ELISA Kit
Cat.#:
JL19323
Regulatory Status:
Alternative:
CD279; PDCD1; SLEB2; HPD1P
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
3.9-250pg/mL
Sensitivity:
1.85pg/mL
Specificity:
This kit recognizes Human PDCD1 in samples. No significant cross-reactivity or interference between Human PDCD1 and analogues was observed.
Sample Type:
Tissue homogenates;cell lysates;cell culture supernates and other biological fluids
Assay Procedure:
Research Area:
Cell Biology
Product Datasheets
| PDCD1
Programmed cell death protein 1 (PD-1), (CD279 cluster of differentiation 279). PD-1 is a protein encoded by the PDCD1 gene.PD-1 is a cell surface receptor on T cells and B cells that has a role in regulating the immune system's response to the cells of the human body by down-regulating the immune system and promoting self-tolerance by suppressing T cell inflammatory activity. This prevents autoimmune diseases, but it can also prevent the immune system from killing cancer cells.PD-1 is an immune checkpoint and guards against autoimmunity through two mechanisms. First, it promotes apoptosis (programmed cell death) of antigen-specific T-cells in lymph nodes. Second, it reduces apoptosis in regulatory T cells (anti-inflammatory, suppressive T cells).| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (pg/mL) | 250 | 125 | 62.5 | 31.25 | 15.62 | 7.81 | 3.9 | 0 |
| OD | 2.22 | 1.56 | 0.92 | 0.63 | 0.42 | 0.25 | 0.18 | 0.08 |
| Corrected OD | 2.14 | 1.48 | 0.84 | 0.55 | 0.34 | 0.17 | 0.1 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human PDCD1 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Tissue Homogenates(n=8) | 85-101 | 96 |
| Cell Culture Supernates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Human PDCD1 and diluted with Universal Diluent to produce samples with values within the range of the assay.| Tissue Homogenates(n=4) | Cell Culture Supernates(n=4) | ||
| 1 : 2 | Range (%) | 84-95 | 90-110 |
| Average (%) | 91 | 96 | |
| 1 : 4 | Range (%) | 89-102 | 105-115 |
| Average (%) | 94 | 108 |
Size
Quantity
Price ($)
48T
1
360 / 360
96T
1
640 / 640