400-0066-400

Human Proteasome Activator Subunit 3 (PSME3;PA28γ) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Human Proteasome Activator Subunit 3 (PSME3;PA28γ) ELISA Kit
Product Name:

Human Proteasome Activator Subunit 3 (PSME3;PA28γ) ELISA Kit

Cat.#:

JL17019

Regulatory Status:
Alternative:

Ki; PA28G; REG-GAMMA; 11S regulator complex subunit gamma; Activator of multicatalytic protease subunit 3; Ki nuclear autoantigen; Proteasome activator 28 subunit gamma

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.156-10ng/mL
Sensitivity:
0.074ng/mL
Specificity:
This kit recognizes Human PSME3;PA28γ in samples. No significant cross-reactivity or interference between Human PSME3;PA28γ and analogues was observed.
Sample Type:
Tissue homogenates;cell lysates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Cell Biology
  • Human Proteasome Activator Subunit 3 (PSME3;PA28γ) ELISA Kit
  • Human Proteasome Activator Subunit 3 (PSME3;PA28γ) ELISA Kit
  • Human Proteasome Activator Subunit 3 (PSME3;PA28γ) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| PSME3;PA28γ

Proteasome activator complex subunit 3 is a protein encoded by the PSME3 gene.Proteasomes are distributed throughout eukaryotic cells at a high concentration and cleave peptides in an ATP/ubiquitin-dependent process in a non-lysosomal pathway. An essential function of a modified proteasome, the immunoproteasome, is the processing of class I MHC peptides. The immunoproteasome contains an alternate regulator, referred to as the 11S regulator or PA28, that replaces the 19S regulator. Three subunits (alpha, beta and gamma) of the 11S regulator have been identified. This gene encodes the gamma subunit of the 11S regulator. Six gamma subunits combine to form a homohexameric ring. Two transcript variants encoding different isoforms have been identified.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (ng/mL) 10 5 2.5 1.25 0.625 0.312 0.156 0
OD 2.22 1.56 0.92 0.63 0.42 0.25 0.18 0.08
Corrected OD 2.14 1.48 0.84 0.55 0.34 0.17 0.1 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Human PSME3;PA28γ spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Tissue Homogenates(n=8) 84-101 96
Cell Lysates(n=8) 96-107 104





 

| Linearity

Samples were spiked with high concentrations of Human PSME3;PA28γ and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Tissue Homogenates(n=4) Cell Lysates(n=4)
1 : 2 Range (%) 84-95 90-110
Average (%) 91 96
1 : 4 Range (%) 89-103 105-115
Average (%) 94 108







 