Product Name:
Human B-cell lymphoma/leukemia 11B (BCL11B) ELISA Kit
Cat.#:
JL52796
Regulatory Status:
Alternative:
BCL11B; ATL1; ATL1-alpha; ATL1-beta; ATL1-delta; ATL1-gamma; CTIP-2; CTIP2; RIT1; ZNF856B; hRIT1-alpha; B-cell CLL/lymphoma 11B; IMD49; B cell CLL/lymphoma 11B; IDDFSTA; BAF complex component; BAF chromatin remodeling complex subunit SMARCM2
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
78.1-5000pg/mL
Sensitivity:
40pg/mL
Specificity:
This kit recognizes Human BCL11B in samples. No significant cross-reactivity or interference between Human BCL11B and analogues was observed.
Sample Type:
Tissue homogenates;cell lysates and other biological fluids
Assay Procedure:
Research Area:
Developmental Biology
Product Datasheets
| BCL11B
B-cell lymphoma/leukemia 11B is a protein that encoded by the BCL11B gene.BCL11B is located on human chromosome 14p32.2.The mouse analogue is called Rit1 or Bcl11b and is located on mouse chromosome 12.This gene encodes a C2H2-type zinc finger protein and is closely related to BCL11A, a gene whose translocation may be associated with B-cell malignancies. The specific function of this gene has not yet been determined, but it could also be involved in some malignancies. Two alternatively spliced transcript variants, which encode distinct isoforms, have been reported.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (pg/mL) | 5000 | 2500 | 1250 | 625 | 312.5 | 156.2 | 78.1 | 0 |
| OD | 2.22 | 1.56 | 0.92 | 0.63 | 0.42 | 0.25 | 0.18 | 0.08 |
| Corrected OD | 2.14 | 1.48 | 0.84 | 0.55 | 0.34 | 0.17 | 0.1 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human BCL11B spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Tissue Homogenates(n=8) | 92-105 | 102 |
| Cell Lysates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Human BCL11B and diluted with Universal Diluent to produce samples with values within the range of the assay.| Tissue Homogenates(n=4) | Cell Lysates(n=4) | ||
| 1 : 2 | Range (%) | 88-96 | 90-110 |
| Average (%) | 93 | 96 | |
| 1 : 4 | Range (%) | 87-108 | 105-115 |
| Average (%) | 98 | 108 |
Size
Quantity
Price ($)
48T
1
280 / 280
96T
1
460 / 460