400-0066-400

Human Somatostatin Receptor Type 2 (SSTR2) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Human Somatostatin Receptor Type 2 (SSTR2) ELISA Kit
Product Name:

Human Somatostatin Receptor Type 2 (SSTR2) ELISA Kit

Cat.#:

JL48164

Regulatory Status:
Alternative:

Smstr2; Sst2

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.156-10ng/mL
Sensitivity:
0.074ng/mL
Specificity:
This kit recognizes Human SSTR2 in samples. No significant cross-reactivity or interference between Human SSTR2 and analogues was observed.
Sample Type:
Tissue homogenates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Metabolism
  • Human Somatostatin Receptor Type 2 (SSTR2) ELISA Kit
  • Human Somatostatin Receptor Type 2 (SSTR2) ELISA Kit
  • Human Somatostatin Receptor Type 2 (SSTR2) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| SSTR2

Somatostatin receptor type 2 is a protein that is encoded by the SSTR2 gene.The somatostatin receptor 2 (SSTR2), which belongs to the G-protein coupled receptor family, is a protein which is most highly expressed in the pancreas (both alpha- and beta-cells), but also in other tissues such as the cerebrum and kidney and in lower amount in the jejunum, colon and liver.In the pancreas, after binding to somatostatin, it inhibits the secretion of peptide hormones from pancreatic islets.During development, it stimulates neuronal migration and axon outgrowth.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (ng/mL) 10 5 2.5 1.25 0.625 0.312 0.156 0
OD 2.22 1.56 0.92 0.63 0.42 0.25 0.18 0.08
Corrected OD 2.14 1.48 0.84 0.55 0.34 0.17 0.1 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Human SSTR2 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Tissue Homogenates(n=8) 84-101 96





 

| Linearity

Samples were spiked with high concentrations of Human SSTR2 and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Tissue Homogenates(n=4)
1 : 2 Range (%) 84-95
Average (%) 91
1 : 4 Range (%) 89-103
Average (%) 94







 