400-0066-400

Human Suppression Of Tumorigenicity 14 Protein (ST14) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Human Suppression Of Tumorigenicity 14 Protein (ST14) ELISA Kit
Product Name:

Human Suppression Of Tumorigenicity 14 Protein (ST14) ELISA Kit

Cat.#:

JL17758

Regulatory Status:
Alternative:

SNC19; HAI; MT-SP1; PRSS14; TADG15; Epithin; Matriptase; Prostamin; Membrane-type serine protease 1; Serine protease 14; Tumor-associated differentially-expressed gene 15

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
1.56-100ng/mL
Sensitivity:
0.8ng/mL
Specificity:
This kit recognizes Human ST14 in samples. No significant cross-reactivity or interference between Human ST14 and analogues was observed.
Sample Type:
Tissue homogenates;cell lysates;cell culture supernates and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Cancer
  • Human Suppression Of Tumorigenicity 14 Protein (ST14) ELISA Kit
  • Human Suppression Of Tumorigenicity 14 Protein (ST14) ELISA Kit
  • Human Suppression Of Tumorigenicity 14 Protein (ST14) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| ST14

Suppressor of tumorigenicity 14 protein, also known as matriptase, is a protein tha is encoded by the ST14 gene.ST14 orthologs have been identified in most mammals for which complete genome data are available.Matriptase is an epithelial-derived, integral membrane serine protease. This protease forms a complex with the Kunitz-type serine protease inhibitor, HAI-1, and is found to be activated by sphingosine-1-phosphate. This protease has been shown to cleave and activate hepatocyte growth factor/scatter factor, and urokinase plasminogen activator, which suggest the function of this protease as an epithelial membrane activator for other proteases and latent growth factors.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (ng/mL) 100 50 25 12.5 6.25 3.12 1.56 0
OD 2.27 1.55 0.96 0.55 0.37 0.26 0.19 0.09
Corrected OD 2.18 1.46 0.87 0.46 0.28 0.17 0.1 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Human ST14 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Tissue Homogenates(n=8) 83-101 96
Cell Lysates(n=8) 92-105 101
Cell Culture Supernates(n=8) 96-108 105





 

| Linearity

Samples were spiked with high concentrations of Human ST14 and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Tissue Homogenates(n=4) Cell Lysates(n=4) Cell Culture Supernates(n=4)
1 : 2 Range (%) 84-95 88-98 90-110
Average (%) 91 93 96
1 : 4 Range (%) 89-103 87-108 105-115
Average (%) 92 98 108







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
280 / 280