Product Name:
Human Mucin 13 (MUC13) ELISA Kit
Cat.#:
JL52825
Regulatory Status:
Alternative:
DRCC1; RECC; Down-Regulated In Colon Cancer 1
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.156-10ng/mL
Sensitivity:
0.079ng/mL
Specificity:
This kit recognizes Human MUC13 in samples. No significant cross-reactivity or interference between Human MUC13 and analogues was observed.
Sample Type:
Tissue homogenates;cell lysates;cell culture supernates and other biological fluids
Assay Procedure:
Research Area:
Signal Transduction
Product Datasheets
| MUC13
Mucin 13(MUC13) is a member of family of secreted and cell surface glycoproteins expressed by ductal and glandular epithelial tissues. MUC13 was expressed on the cell surface and underwent N- and O-glycosylation. MUC13 was cleaved internally to produce an N-terminal mucin subunit, called the alpha subunit, and a C-terminal beta subunit that included the transmembrane region. Beta subunits appeared to undergo homodimerization that was dependent on intrachain disulfide bonds.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (ng/mL) | 10 | 5 | 2.5 | 1.25 | 0.625 | 0.312 | 0.156 | 0 |
| OD | 2.17 | 1.74 | 1.17 | 0.78 | 0.47 | 0.32 | 0.23 | 0.08 |
| Corrected OD | 2.09 | 1.66 | 1.09 | 0.7 | 0.39 | 0.24 | 0.15 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human MUC13 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Tissue Homogenates(n=8) | 84-101 | 97 |
| Cell Lysates(n=8) | 92-104 | 102 |
| Cell Culture Supernates(n=8) | 96-108 | 106 |
| Linearity
Samples were spiked with high concentrations of Human MUC13 and diluted with Universal Diluent to produce samples with values within the range of the assay.| Tissue Homogenates(n=4) | Cell Lysates(n=4) | Cell Culture Supernates(n=4) | ||
| 1 : 2 | Range (%) | 84-95 | 88-96 | 90-110 |
| Average (%) | 91 | 93 | 96 | |
| 1 : 4 | Range (%) | 89-103 | 87-108 | 105-115 |
| Average (%) | 95 | 98 | 108 |
Size
Quantity
Price ($)
48T
1
280 / 280
96T
1
460 / 460