Product Name:
Human Pulmonary Surfactant-associated Protein C (SP-C) ELISA Kit
Cat.#:
JL11024
Regulatory Status:
Alternative:
BRICD6; BRICHOS domain containing 6; PSP C; PSPC; PSPC_HUMAN; Pulmonary surfactant apoprotein 2; Pulmonary surfactant apoprotein PSP C; pulmonary surfactant apoprotein-2 SP-C; Pulmonary surfactant associated protein C; Pulmonary surfactant associated prot
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.312-20ng/mL
Sensitivity:
0.153ng/mL
Specificity:
This kit recognizes Human SP-C in samples. No significant cross-reactivity or interference between Human SP-C and analogues was observed.
Sample Type:
Serum; plasma; tissue homogenates and other biological fluids
Assay Procedure:
Research Area:
Epigenetics
Product Datasheets
| SP-C
Surfactant protein C (SP-C), is one of the pulmonary surfactant proteins. It is encoded by the SFTPC gene.It is a membrane protein.SFTPC is a 197-residue protein made up of two halves: a unique N-terminal propeptide domain and a C-terminal BRICHOS domain. The around 100-aa long propeptide domain actually contains not only the cleaved part, but also the mature peptide. It can be further broken down into a 23-aa helical transmembrane propeptide proper, the mature secreted SP-C (24-58), and a linker (59-89) that connects to the BRICHOS domain.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (ng/mL) | 20 | 10 | 5 | 2.5 | 1.25 | 0.625 | 0.312 | 0 |
| OD | 2.22 | 1.56 | 0.92 | 0.63 | 0.42 | 0.25 | 0.18 | 0.08 |
| Corrected OD | 2.14 | 1.48 | 0.84 | 0.55 | 0.34 | 0.17 | 0.1 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human SP-C spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Serum(n=8) | 84-101 | 96 |
| Plasma(n=8) | 92-105 | 102 |
| Cell Culture Supernates(n=8) | 95-108 | 104 |
| Linearity
Samples were spiked with high concentrations of Human SP-C and diluted with Universal Diluent to produce samples with values within the range of the assay.| Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
| 1 : 2 | Range (%) | 84-95 | 88-96 | 90-110 |
| Average (%) | 91 | 93 | 96 | |
| 1 : 4 | Range (%) | 89-103 | 87-107 | 105-115 |
| Average (%) | 94 | 97 | 108 |
Size
Quantity
Price ($)
48T
1
280 / 280
96T
1
460 / 460