Product Name:
Human Epidermal Growth Factor Receptor 3 (HER3) ELISA Kit
Cat.#:
JL43209
Regulatory Status:
Alternative:
HER3; MDA-BF-1; C-ErbB3; LCCS2; ErbB3-S; P180-ErbB3; P45-SErbB3; P85-SErbB3; Receptor Tyrosine-Protein Kinase ErbB-3; Lethal Congenital Contracture Syndrome 2;V-Erb B2 Erythroblastic Leukemia Viral Oncogene Homolog 3
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
78.12-5000pg/mL
Sensitivity:
39pg/mL
Specificity:
This kit recognizes Human HER3 in samples. No significant cross-reactivity or interference between Human HER3 and analogues was observed.
Sample Type:
Serum;plasma;tissue homogenates;cell lysates;cell culture supernates and other biological fluids
Assay Procedure:
Research Area:
Signal Transduction
Product Datasheets
| HER3
Human epidermal growth factor receptor (HER3) also known as erbB-3 (3Receptor tyrosine-protein kinase), is a membrane bound protein that in humans is encoded by the ERBB3 gene.ErbB3 is a member of the epidermal growth factor receptor (EGFR/ERBB) family of receptor tyrosine kinases. The kinase-impaired ErbB3 is known to form active heterodimers with other members of the ErbB family, most notably the ligand binding-impaired ErbB2.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (pg/mL) | 5000 | 2500 | 1250 | 625 | 312.5 | 156.25 | 78.12 | 0 |
| OD | 2.52 | 1.96 | 1.38 | 0.97 | 0.55 | 0.31 | 0.19 | 0.08 |
| Corrected OD | 2.44 | 1.88 | 1.3 | 0.89 | 0.47 | 0.23 | 0.11 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human HER3 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Serum(n=8) | 85-101 | 96 |
| Plasma(n=8) | 92-105 | 100 |
| Tissue Homogenates(n=8) | 96-106 | 105 |
| Linearity
Samples were spiked with high concentrations of Human HER3 and diluted with Universal Diluent to produce samples with values within the range of the assay.| Serum(n=4) | Plasma(n=4) | Tissue Homogenates(n=4) | ||
| 1 : 2 | Range (%) | 84-95 | 88-96 | 90-110 |
| Average (%) | 91 | 93 | 96 | |
| 1 : 4 | Range (%) | 89-103 | 87-108 | 105-115 |
| Average (%) | 94 | 98 | 108 |
Size
Quantity
Price ($)
48T
1
280 / 280
96T
1
460 / 460