Product Name:
Human Acidic Isoferitin (AIF) ELISA Kit
Cat.#:
JL15174
Regulatory Status:
Alternative:
acidic isoferitin
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.156-10ng/mL
Sensitivity:
0.08ng/mL
Specificity:
This kit recognizes Human AIF in samples. No significant cross-reactivity or interference between Human AIF and analogues was observed.
Sample Type:
Serum;plasma;tissue homogenates;cell lysates;cell culture supernates and other biological fluids
Assay Procedure:
Research Area:
Neuroscience
Product Datasheets
| AIF
Acidic Isoferitin(AIF) is an acidic isomer of ferritin, rich in H subunit, with a slightly acidic isoelectric point, prone to form polymers, and has a different antigenic composition from other ferritin proteins.Mainly present in liver cancer tissues, cardiomyocytes and neutrophil granulosa cells, as a potential tumor marker.The glycosylation modification of AIF protein in serum is relatively complete after synthesis. However, in tissues such as myocardial infarction where cells rupture and are released into the blood, the glycosylation of AIF is incomplete, and the blood circulation has an extremely fast clearance speed for it, which does not interfere with the determination of AIF in serum.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (ng/mL) | 10 | 5 | 2.5 | 1.25 | 0.625 | 0.312 | 0.156 | 0 |
| OD | 2.11 | 1.28 | 0.71 | 0.4 | 0.3 | 0.22 | 0.18 | 0.08 |
| Corrected OD | 2.03 | 1.2 | 0.63 | 0.32 | 0.22 | 0.14 | 0.1 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human AIF spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Serum(n=8) | 84-101 | 96 |
| Plasma(n=8) | 92-105 | 103 |
| Cell Culture Supernates(n=8) | 96-108 | 105 |
| Linearity
Samples were spiked with high concentrations of Human AIF and diluted with Universal Diluent to produce samples with values within the range of the assay.| Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
| 1 : 2 | Range (%) | 84-95 | 88-96 | 90-110 |
| Average (%) | 91 | 93 | 96 | |
| 1 : 4 | Range (%) | 89-103 | 87-108 | 105-114 |
| Average (%) | 94 | 98 | 107 |
Size
Quantity
Price ($)
48T
1
280 / 280
96T
1
460 / 460