Product Name:
Human Collectin Sub-family Member 11 (COLEC11) ELISA Kit
Cat.#:
JL14807
Regulatory Status:
Alternative:
CL K1;CL K1 I;CL K1 II;CL K1 IIa;CL K1 IIb;CL-K1;CLK1;COL11_HUMAN;COLEC 11;COLEC11;Collectin 11;Collectin kidney I;Collectin kidney protein 1;Collectin sub family member 11;Collectin-11;Collectin11;DKFZp686N1868;MGC129470;MGC129471;MGC3279
Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
31.2-2000pg/mL
Sensitivity:
15.2pg/mL
Specificity:
This kit recognizes Human COLEC11 in samples. No significant cross-reactivity or interference between Human COLEC11 and analogues was observed.
Sample Type:
Serum;plasma and other biological fluids
Assay Procedure:
Research Area:
Cell Biology
Product Datasheets
| COLEC11
Collectin sub-family member 11(COLEC11) is a member of the collectin family of C-type lectins that possess collagen-like sequences and carbohydrate recognition domains. Collectins are secreted proteins that play important roles in the innate immune system by binding to carbohydrate antigens on microorganisms, facilitating their recognition and removal. The protein binds to multiple sugars with a preference for fucose and mannose.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (pg/mL) | 2000 | 1000 | 500 | 250 | 125 | 62.5 | 31.2 | 0 |
| OD | 2.22 | 1.56 | 0.92 | 0.63 | 0.42 | 0.25 | 0.18 | 0.08 |
| Corrected OD | 2.14 | 1.48 | 0.84 | 0.55 | 0.34 | 0.17 | 0.1 | - |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Human COLEC11 spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Serum(n=8) | 84-101 | 95 |
| Plasma(n=8) | 92-106 | 103 |
| Linearity
Samples were spiked with high concentrations of Human COLEC11 and diluted with Universal Diluent to produce samples with values within the range of the assay.| Serum(n=4) | Plasma(n=4) | ||
| 1 : 2 | Range (%) | 84-95 | 88-95 |
| Average (%) | 91 | 93 | |
| 1 : 4 | Range (%) | 89-103 | 87-107 |
| Average (%) | 94 | 98 |
Size
Quantity
Price ($)
48T
1
280 / 280
96T
1
460 / 460


