400-0066-400

Human Lactoperoxidase (LPO) ELISA Kit

Home  >  Sandwich ELISA Kits  >  Human Lactoperoxidase (LPO) ELISA Kit
Product Name:

Human Lactoperoxidase (LPO) ELISA Kit

Cat.#:

JL15102

Regulatory Status:
Alternative:

SPO; Salivary peroxidase

Detection Method:
ELISA
Assay Type:
Sandwich
Detection Range:
0.15-10ng/mL
Sensitivity:
0.05ng/mL
Specificity:
This kit recognizes Human LPO in samples. No significant cross-reactivity or interference between Human LPO and analogues was observed.
Sample Type:
Breast milk, tear and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Immunology
  • Human Lactoperoxidase (LPO) ELISA Kit
  • Human Lactoperoxidase (LPO) ELISA Kit
  • Human Lactoperoxidase (LPO) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| LPO

Lactoperoxidase is a peroxidase enzyme secreted from mammary, salivary, tears and other mucosal glands including the lungs, bronchii and nose that function as a natural, first line of defense against bacteria and viral agents. Lactoperoxidase is a member of the heme peroxidase family of enzymes. Lactoperoxidase is encoded by the LPO gene.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (ng/mL) 10 5 2.5 1.25 0.62 0.31 0.15 0
OD 2.53 1.94 1.39 1.19 0.76 0.43 0.26 0.08
Corrected OD 2.45 1.86 1.31 1.11 0.68 0.35 0.18 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Human LPO spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Breast Milk(n=8) 84-101 96
Tears(n=8) 92-105 102





 

| Linearity

Samples were spiked with high concentrations of Human LPO and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Breast Milk(n=4) Tears(n=4)
1 : 2 Range (%) 85-95 88-96
Average (%) 91 93
1 : 4 Range (%) 89-103 87-108
Average (%) 94 98







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
280 / 280
96T
1
460 / 460