400-0066-400

Human Anti-Nucleosome Antibody IgG (AnuA-IgG) ELISA Kit

Home  >  Indirect ELSA Kits  >  Human Anti-Nucleosome Antibody IgG (AnuA-IgG) ELISA Kit
Product Name:

Human Anti-Nucleosome Antibody IgG (AnuA-IgG) ELISA Kit

Cat.#:

JL10714

Regulatory Status:
Alternative:

AnuA-IgG

Detection Method:
ELISA
Assay Type:
Indirect
Detection Range:
1.56-100ng/mL
Sensitivity:
0.66ng/mL
Specificity:
This kit recognizes Human AnuA-IgG in samples. No significant cross-reactivity or interference between Human AnuA-IgG and analogues was observed.
Sample Type:
Serum, plasma
Assay Procedure:
Assay Procedure
Research Area:
Immunology
  • Human Anti-Nucleosome Antibody IgG (AnuA-IgG) ELISA Kit
  • Human Anti-Nucleosome Antibody IgG (AnuA-IgG) ELISA Kit
  • Human Anti-Nucleosome Antibody IgG (AnuA-IgG) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| AnuA-IgG

The nucleosome is the basic structural unit of eukaryotic chromatin, formed by approximately 147 base pairs of DNA wrapped around an octameric core composed of two molecules each of the four histones H2A, H2B, H3, and H4, giving it a "beads-on-a-string" appearance. Adjacent nucleosomes are connected by linker DNA, and histone H1 participates in stabilizing higher-order structures. Nucleosomes compact and package DNA into the nucleus and regulate gene expression through histone modifications, making them an important carrier of epigenetics.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (ng/mL) 100 50 25 12.5 6.25 3.12 1.56 0
OD 2.65 1.86 1.16 0.85 0.6 0.44 0.37 0.16
Corrected OD 2.49 1.7 1 0.69 0.44 0.28 0.21 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Human AnuA-IgG spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 86-103 99
Plasma(n=8) 94-108 102





 

| Linearity

Samples were spiked with high concentrations of Human AnuA-IgG and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4)
1 : 2 Range (%) 82-101 88-103
Average (%) 95 100
1 : 4 Range (%) 83-100 97-115
Average (%) 92 110







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
320 / 320
96T
1
576 / 576
Top