400-0066-400

Human Anti-Glomerular Basement Membrane IgG (Anti-GBM IgG) ELISA Kit

Home  >  Indirect ELSA Kits  >  Human Anti-Glomerular Basement Membrane IgG (Anti-GBM IgG) ELISA Kit
Product Name:

Human Anti-Glomerular Basement Membrane IgG (Anti-GBM IgG) ELISA Kit

Cat.#:

JL55219

Regulatory Status:
Alternative:

Anti-GBM IgG

Detection Method:
ELISA
Assay Type:
Indirect
Detection Range:
1.56-100ng/mL
Sensitivity:
0.62ng/mL
Specificity:
This kit recognizes Human Anti-GBM IgG in samples. No significant cross-reactivity or interference between Human Anti-GBM IgG and analogues was observed.
Sample Type:
Serum, plasma, and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Immunology
  • Human Anti-Glomerular Basement Membrane IgG (Anti-GBM IgG) ELISA Kit
  • Human Anti-Glomerular Basement Membrane IgG (Anti-GBM IgG) ELISA Kit
  • Human Anti-Glomerular Basement Membrane IgG (Anti-GBM IgG) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| Anti-GBM IgG

Goodpasture syndrome (GPS), also known as anti-glomerular basement membrane disease, is a rare autoimmune disorder in which antibodies attack the basement membranes of the lungs and kidneys, leading to pulmonary hemorrhage, glomerulonephritis, and renal failure. It is recognized that these antibodies target the alpha-3 subunit of type IV collagen, which is referred to as the Goodpasture antigen. Anti-glomerular basement membrane antibodies (anti-GBM antibodies) are specifically detected in Goodpasture syndrome but are not found in microscopic polyangiitis. Although anti-GBM antibodies primarily attack the kidneys and lungs, systemic symptoms such as malaise, weight loss, fatigue, fever, and chills are also common, and joint pain is frequently observed.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (ng/mL) 100 50 25 12.5 6.25 3.12 1.56 0
OD 2.79 2.46 1.65 0.94 0.57 0.35 0.28 0.05
Corrected OD 2.74 2.41 1.6 0.89 0.52 0.3 0.23 -
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of Human Anti-GBM IgG spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 81-111 99
Plasma(n=8) 82-107 100





 

| Linearity

Samples were spiked with high concentrations of Human Anti-GBM IgG and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4)
1 : 2 Range (%) 92-111 82-109
Average (%) 98 94
1 : 4 Range (%) 91-107 88-108
Average (%) 99 99







 
Close
Sample Data
Close
Sample Data
Close
Sample Data
Size Quantity Price ($)
48T
1
400 / 400
96T
1
560 / 560
Top