400-0066-400

Noradrenaline (NE) ELISA Kit

Home  >  Competitive ELISA Kits  >  Noradrenaline (NE) ELISA Kit
Product Name:

Noradrenaline (NE) ELISA Kit

Cat.#:

JL54495

Regulatory Status:
Alternative:

NA; NAd; Norepinephrine; Norepi

Detection Method:
ELISA
Assay Type:
Competitive
Detection Range:
78-5000pg/mL
Sensitivity:
40pg/mL
Specificity:
This kit recognizes NE in samples. No significant cross-reactivity or interference between NE and analogues was observed.
Sample Type:
Serum, plasma, cell culture supernatants and other biological fluids
Assay Procedure:
Assay Procedure
Research Area:
Neuroscience
  • Noradrenaline (NE) ELISA Kit
  • Noradrenaline (NE) ELISA Kit
  • Noradrenaline (NE) ELISA Kit
Size & Price: cart
×
Human A1BG Polyclonal Antibody
Email *
Message *
Please Sign In.
Product Datasheets
Instruction: Down Instruction


| NE

Norepinephrine (INN name: Norepinephrine, also known as Noradrenaline, abbreviated as NE or NA), formerly called "noradrenaline," has the chemical name 1-(3,4-dihydroxyphenyl)-2-aminoethanol. It is the substance formed when the N-methyl group is removed from epinephrine, and structurally it also belongs to the catecholamines. It is both a neurotransmitter, mainly synthesized and secreted by postganglionic sympathetic neurons and noradrenergic neurons in the brain, and is the primary transmitter released by the latter, and a hormone, synthesized and secreted by the adrenal medulla, though in relatively small amounts. Norepinephrine in the circulating blood mainly comes from the adrenal medulla.
 

| Typical data

As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.

 
Concentration (pg/mL) 5000 2500 1250 625 312 156 78 0
OD 0.216 0.298 0.417 0.669 0.955 1.405 1.79 1.865
 





| Repeatability

Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%
 

| Recovery

The recovery of NE spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.

 
Sample Type Range(%) Average Recovery(%)
Serum(n=8) 81-101 96
Plasma(n=8) 92-105 101
Cell Culture Supernates(n=8) 97-108 105





 

| Linearity

Samples were spiked with high concentrations of NE and diluted with Universal Diluent to produce samples with values within the range of the assay.

 
    Serum(n=4) Plasma(n=4) Cell Culture Supernates(n=4)
1 : 2 Range (%) 83-95 88-96 90-110
Average (%) 91 93 96
1 : 4 Range (%) 89-104 87-108 105-115
Average (%) 93 98 110







 