Product Name:
Clenbuterol Hydrochloride (Clenbuterol hydrochloride) ELISA Kit
Cat.#:
JL18711
Regulatory Status:
Alternative:
Clenbuterol hydrochloride
Detection Method:
ELISA
Assay Type:
Competitive
Detection Range:
7.8-500pg/mL
Sensitivity:
4.2pg/mL
Specificity:
This kit recognizes Clenbuterol hydrochloride in samples. No significant cross-reactivity or interference between Clenbuterol hydrochloride and analogues was observed.
Sample Type:
Serum;plasma;tissue homogenates;cell lysates;cell culture supernates and other biological fluids
Assay Procedure:
Research Area:
Pesticide Residues & Drug Metabolism
Product Datasheets
| Clenbuterol hydrochloride
Clenbuterol is a sympathomimetic amine used by sufferers of breathing disorders as a decongestant and bronchodilator. People with chronic breathing disorders such as asthma use this as a bronchodilator to make breathing easier. It is most commonly available as the hydrochloride salt, clenbuterol hydrochloride.Clenbuterol is a β2 agonist with some structural and pharmacological similarities to epinephrine and salbutamol, but its effects are more potent and longer-lasting as a stimulant and thermogenic drug.It is commonly used for smooth muscle-relaxant properties as a bronchodilator and tocolytic.| Typical data
As the OD values of the standard curve may vary according to the conditions of the actual assay performance (e.g. operator, pipetting technique, wash technique or temperature effects), the operator should establish a standard curve for each test. Typical standard curve and data are provided below for reference only.| Concentration (pg/mL) | 500 | 250 | 125 | 62.5 | 31.2 | 15.6 | 7.8 | 0 |
| OD | 0.216 | 0.298 | 0.417 | 0.669 | 0.955 | 1.405 | 1.79 | 1.865 |
| Corrected OD |
| Repeatability
Intra-assay Precision (Precision within an assay):CV% < 10%; Inter-assay Precision (Precision between assays):CV% < 10%| Recovery
The recovery of Clenbuterol hydrochloride spiked at three different levels in samples throughout the range of the assay was evaluated in various matrices.| Sample Type | Range(%) | Average Recovery(%) |
| Serum(n=8) | 81-101 | 96 |
| Plasma(n=8) | 92-105 | 101 |
| Cell Culture Supernates(n=8) | 97-109 | 105 |
| Linearity
Samples were spiked with high concentrations of Clenbuterol hydrochloride and diluted with Universal Diluent to produce samples with values within the range of the assay.| Serum(n=4) | Plasma(n=4) | Cell Culture Supernates(n=4) | ||
| 1 : 2 | Range (%) | 83-95 | 88-96 | 90-110 |
| Average (%) | 91 | 93 | 96 | |
| 1 : 4 | Range (%) | 89-104 | 87-108 | 105-115 |
| Average (%) | 93 | 98 | 110 |